久久国产精品无码网站_3D动漫同人精品无码专区_亚洲AV永久无码精品网址_无码天堂亚洲国产AV

Isolation transformer for imported equipment

PRODUCT

CONTACT US

Tel:400-685-8582

Tel:+86-21-57715555
           +86-21-37831986

Fax:+86-21-37831846

Phone:

Email:weho@chinaweho. com

 Address:Building 2, No.8 Nanle Road, Songjiang District, Shanghai

Isolation transformer for imported equipment

Isolation transformer for imported equipment Isolation transformer for imported equipment

Isolation transformer for imported equipment

  • Category:Isolation transformer for imported equipment
  • product description SG-F series imported equipment supporting three-phase dry-type isolation transformer is a new generation of energy-saving power transformer developed and produced by our factory on the basis of referring to similar products and
  • Hotline:   
Product Description

product description

SG-F series imported equipment supporting three-phase dry-type isolation transformer is a new generation of energy-saving power transformer developed and produced by our factory on the basis of referring to similar products and combining my country's national conditions. The winding adopts the method of unfinished and whole-column winding; the transformer is vacuum dipped, so that the insulation level of the transformer can reach the F level or H level, and the product performance has reached the advanced level at home and abroad. SG-F series three-phase dry-type isolation transformers are widely used in circuits with AC 50Hz to 60Hz and voltage below 3300V. . The various input and output voltage levels of the product, the connection group, the number and position of the adjustment taps (generally ±5%), the distribution of the winding capacity, the configuration of the secondary single-phase winding, the use of the rectifier circuit, whether the belt is required Shells, etc., can be carefully designed and manufactured according to user requirements.

Features

 Establishing a new neutral line-grounding in the isolation transformer can relieve the common mode interference of the power grid and the troubles of other neutral lines. The isolation transformer converts the three-wire △ connection into a four-wire Yo system, and the shielding further eliminates the high-frequency pulse interference coupled by the transformer. Although the shielded isolation transformer can effectively prevent interference from various NGs (pulse and high-frequency noise), the transformer must be properly grounded and very strict, otherwise the anti-common mode interference will be ineffective. The company can design and produce high-quality isolation transformers for customers.

Features advantages:

?High isolation

?N-G has good performance

?High common mode interference rejection

? Convert △ to Y or Y to △

? Voltage taps are easy to change

 ?Designed according to the special performance requirements of users

Technical indicators

 1. Input rated voltage: three-phase 380V or single-phase 380V or single-phase 220V

 2. Output rated voltage: three-phase 220V/200V/208V/230V/480V or single-phase 110V/120V/127V/

3. Working frequency: 50Hz-60Hz

4. Efficiency: ≥95%

5. Temperature rise: <60K

6. Waveform distortion: <0.1%

 7. High voltage test: 2500V, no breakdown for 1 minute

 8. Insulation resistance: winding to ground insulation resistance ≥ 500M ohms, primary to secondary insulation resistance ≥ 500M ohms


Shape and installation dimensions

model Capacity (KVA) Output voltage (V) join group number Dimensions (mm)
enter output account opening protective
Bmax Dmax Emax Bmax Dmax Dmax
SG-F-0.15 0.15 660
380
220
380
220
200
127
V/V
Y/yno(Y/yo)
Y/d(Y/)
D/Y(△/Y)
Y/d(△/△)
200 105 140 260 180 160
SG-F -0.3 0.3 180 110 180 260 180 160
SG-F -0.5 0.5 180 115 180 260 200 120
SG-F -0.75 0.75 230 130 200 260 250 260
SG-F-1 1 230 140 200 315 200 260
SG-F-1.5 1.5 230 155 200 355 290 280
SG-F-2 2 270 165 250
SG-F-2.5 2.5 270 175 250 370 290 300
SG-F-3 3 270 185 250
SG-F-4 4 300 180 285 510 400 550
SG-F-5 5 300 200 285
SG-F-10 10 370 210 240 560 430 600
SG-F-15 15 420 245 390 600 440 620
SG-F-20 20 540 320 450 650 440 650
SG-F-30 30 540 380 480 870 500 780
SG-F-40 40 750 350 520 960 550 810
SG-F-50 50
SG-F-60 60 800 450 650 1000 810 810
SG-F-80 80
SG-F-100 100 860 450 650 1050 810 810
SG-F-125 125 860 500 700
SG-F-160 160 950 600 800
SG-F-200 200 1000 680 850
SG-F-250 250 1050 700 850

Conditions of Use

1. Applicable altitude: ≤5000m

2. Ambient temperature: -15℃~+45℃

3. Relative humidity: ≤90%

 4. The installation site should be free of gas, steam, chemical deposits, dirt, conductive dust and other explosive, flammable and corrosive substances that seriously affect the insulation strength of the transformer.

 5. Those that do not meet the above conditions of use should be negotiated with us.