PRODUCT
Tel:400-685-8582
Tel:+86-21-57715555
+86-21-37831986
Fax:+86-21-37831846
Phone:
Email:weho@chinaweho. com
Address:Building 2, No.8 Nanle Road, Songjiang District, Shanghai
Shielded isolation transformer eliminates neutral ground voltage
- Category:380V to 380V filtering anti-interference isolation transformer
- product description SG-P (DG-P) series products are imported high-quality cold-rolled silicon steel sheets, with reasonable structure, high reliability, anti-interference, good safety performance, high efficiency, low noise, and are widely used in
- Hotline:
product description
SG-P (DG-P) series products are imported high-quality cold-rolled silicon steel sheets, with reasonable structure, high reliability, anti-interference, good safety performance, high efficiency, low noise, and are widely used in UPS bypass and neutral ground voltage removal. , Imported equipment with high requirements for pure sine wave power supply voltage and other occasions.
The transformer adopts three-column iron core, Y/Y0 or △/Y0 connection, good insulation between the primary and auxiliary coils, and adopts double shielding isolation (adding shielding further eliminates the high-frequency pulse interference and noise coupled by the transformer, However, although the shielded isolation transformer can effectively prevent interference from various NGs (pulse and high-frequency noise), the transformer must be properly grounded). The secondary circuit is protected from power grid and external high-frequency electromagnetic wave interference and safe manual operation. The body is installed in the protective net cover to ensure good heat dissipation.
Models and what they mean
Features and advantages
★High isolation ★Good NG performance
★High common mode interference rejection
★Convert △ to Y or Y to △
★The voltage tap is easy to change
★Designed according to the user's special performance requirements
The main technical parameters
Input voltage |
Single-phase 220V±10% Three-phase 380V±10% (three-phase three-wire) |
efficient | >96% |
waveform distortion | ≤0.1% | ||
The output voltage |
Single-phase 220V±3%PE (two-phase three-wire) three-phase 380V±3%PE (three-phase five-wire) |
Response time | 20ms-100ms |
frequency | 50/60Hz | ambient temperature | -10℃-+45℃ |
temperature rise | ≤80℃ | audio noise | ≤60dB distance 1m |
Dielectric strength | 2000V/min | Insulation resistance | Single-phase>5MΩ Three-phase>2MΩ |
Shape and installation dimensions
model | Capacity (KVA) | Output voltage (V) | join group number | Dimensions (mm) | ||||||
enter | output | account opening | protective | |||||||
Bmax | Dmax | Emax | Bmax | Dmax | Dmax | |||||
SG-P-0.15 | 0.15 |
660 380 220 |
380 220 200 127 |
V/V Y/yno(Y/yo) Y/d(Y/) D/Y(△/Y) Y/d(△/△) |
200 | 105 | 140 | 260 | 180 | 160 |
SG-P -0.3 | 0.3 | 180 | 110 | 180 | 260 | 180 | 160 | |||
SG-P -0.5 | 0.5 | 180 | 115 | 180 | 260 | 200 | 120 | |||
SG-P -0.75 | 0.75 | 230 | 130 | 200 | 260 | 250 | 260 | |||
SG-P-1 | 1 | 230 | 140 | 200 | 315 | 200 | 260 | |||
SG-P-1.5 | 1.5 | 230 | 155 | 200 | 355 | 290 | 280 | |||
SG-P-2 | 2 | 270 | 165 | 250 | ||||||
SG-P -2.5 | 2.5 | 270 | 175 | 250 | 370 | 290 | 300 | |||
SG-P-3 | 3 | 270 | 185 | 250 | ||||||
SG-P-4 | 4 | 300 | 180 | 285 | 510 | 400 | 550 | |||
SG-P-5 | 5 | 300 | 200 | 285 | ||||||
SG-P-10 | 10 | 370 | 210 | 240 | 560 | 430 | 600 | |||
SG-P-15 | 15 | 420 | 245 | 390 | 600 | 440 | 620 | |||
SG-P-20 | 20 | 540 | 320 | 450 | 650 | 440 | 650 | |||
SG-P-30 | 30 | 540 | 380 | 480 | 870 | 500 | 780 | |||
SG-P-40 | 40 | 750 | 350 | 520 | 960 | 550 | 810 | |||
SG-P-50 | 50 | |||||||||
SG-P-60 | 60 | 800 | 450 | 650 | 1000 | 810 | 810 | |||
SG-P-80 | 80 | |||||||||
SG-P-100 | 100 | 860 | 450 | 650 | 1050 | 810 | 810 | |||
SG-P-125 | 125 | 860 | 500 | 700 | ||||||
SG-P-160 | 160 | 950 | 600 | 800 | ||||||
SG-P-200 | 200 | 1000 | 680 | 850 | ||||||
SG-P-250 | 250 | 1050 | 700 | 850 |
Conditions of Use
1. Applicable altitude: ≤5000m
2. Ambient temperature: -15℃~+45℃
3. Relative humidity: ≤90%
4. The installation site should be free of gas, steam, chemical deposits, dirt, conductive dust and other explosive, flammable and corrosive substances that seriously affect the insulation strength of the transformer.
5. Those that do not meet the above conditions of use should be negotiated with us.